Important Safeguards/Conventions
Instructions – WB5GT Water Boiler
This appliance is designed for commercial use. Any servicing other than cleaning and
maintenance should be performed by an authorized Wilbur Curtis service center.
•DoNOTimmersetheunitinwateroranyotherliquid
•Nevercleanwithscouringpowders,bleachorharshimplements.
Conventions:
WARNINGS–Tohelpavoidpersonalinjury ImportantNotes/Cautions
SanitationRequirements
Curtis WB5GT Units are Factory Pre-Set and Ready to Go… Right out of the Carton.
Generallytherewillneverbeareasontochangefactorysettings,howeveradjustment
instructions are provided later in this manual.
SystemRequirements:
• WaterSource20–100PSI(MinimumFlowRateof1GPM)
• Waterpipeconnectionsandxturesdirectlyconnectedtoapotablewatersupply
shallbesized,installedandmaintainedinaccordancewithfederal,state,and
local codes.
SETUP STEPS
1.Placeunitatcounterheight.onarm,levelbase,insuchawaythatitcanbecon-
nectedtowaterandpowersupply.
2.Connectwaterlinetoinletttingonvalve.Itisrecommendedthatsometypeofwater
mineralreducinglterbeusedinthewaterlinebeforeenteringtheunit.Waterpres-
sureenteringboilerismustbestableandprovideminimumof1gallonperminute.Use
waterregulatorforconstantpressure.Requiredwaterpressures,20to100psi.Turn
onwatervalve.
3.Hook-uppowertotheunit(refertoschematicforpowerrequirements).
4.Turnonelectricalpowertounit.Thewaterinletvalvewillopenandstartllingtheunit.
Whenthewaterlevelinthetankrisestothecorrectvolume,theheatingelementswill
energize automatically.
5.Heatingtankwillrequire60to70minutestoattainoperatingtemperature.READY
indicatoroncontrolpanelwilllightatthistime.
Wi l b u r Cu r t i s Co m p a n y , in C .
ModelsIncluded
•WB5GT
CAUTION: Please use
this setup procedure
before attempting to use
this brewer. Failure to follow the
instructions can result in injury or the
voiding of the warranty.
WARNING HOT LIQUID,
Scalding may occur.
Avoid splashing.
CAUTION: DO NOT
connect this unit to hot
water. The inlet valve is
not rated for hot water.
WILBUR CURTIS COMPANY
Montebello, CA 90640
3.5”
(8.9 cm)
21.125”
(53.7 cm)
9.25”
(23.5 cm)
24.5”
(62.2 cm)
13.5”
(34.3 cm)
16.625”
(42.2 cm)
WB5GT
Rough-In
Drawing
NSF International requires the following water connection:
1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) so that
the machine can be moved for cleaning underneath.
2. Thisequipmentistobeinstalledwithadequatebackowprotectiontocomplywith
applicable federal, state and local codes..
3. Waterpipeconnectionsandxturesdirectlyconnectedtoapotablewatersupplyshall
be sized, installed and maintained in accordance with federal, state, and local codes.